loading
The BKMAMLAB ATP meter (also referred to as an ATP tester, ATP luminometer, or ATP hygiene meter) is a high-performance instrument designed for rapid microbial contamination screening. Using bioluminescence technology, this ATP bioluminescence meter quantifies microorganisms by measuring ATP concentration from 0 to 120,000 RLU in just 10 seconds.
With an ultra-high sensitivity detection limit of ≤1.0 CFU/mL and accuracy up to 2×10⁻¹⁵ mol ATP, this ATP detection device is capable of screening for coliform bacteria (≥1×10⁵ CFU). The 3.5-inch IPS touchscreen provides clear results with automatic three-color indicators (green/yellow/red) for intuitive Pass/Alert/Fail readings. Whether you need an ATP monitor for food processing lines or a luminometer for pharmaceutical cleanrooms, BKMAMLAB delivers reliable and portable hygiene monitoring.
Parameter | BATP-100 |
|---|---|
Detection Range | 0 – 120,000 RLU |
Detection Time | 10 seconds |
Detection Accuracy | 2 × 10⁻¹⁵ mol ATP |
Detection Limit | ≤1.0 CFU/mL |
Coliform Detection Range | ≥1 × 10⁵ CFU (for E. coli only) |
Detection Interference | ±5% or ±5 RLUs |
Background Value | ≤2 RLU |
Detection Mode | RLU or coliform screening |
Storage Capacity | 2,000 test results |
USB Interface | Type-C, supports data transfer to PC |
Operating Temperature | 5–40 °C |
Relative Humidity | 20–85% |
Battery Type | Lithium battery |
Rated Input | DC 5 V, 2 A |
Product Dimensions | 179.3 × 70 × 40.5 mm |
Zero-Calibration Time | 10 seconds |
Product Weight | 251.8 g |
The ATP meter delivers test results in just 10 seconds with a simple one-button start. No cultivation is required—test directly after sample collection. This ATP testing machine significantly speeds up hygiene monitoring compared to traditional culture-based methods.
Test results are automatically highlighted with three colors for improved readability:
Green: Pass status (≤100 RLU)
Yellow: Warning status (100–200 RLU)
Red: Fail status (>200 RLU)
This ATP tester provides clear, intuitive results without the need for professional training.
The ATP luminometer features a 3.5-inch IPS full-view display with high contrast and brightness. The precise touch control makes operation simple and responsive, enhancing user experience during on-site testing.
This ATP detection device stores up to 2,000 records with custom naming of tests. It supports quick data export to PC via Type-C USB in CSV format (Excel/WPS compatible). The ATP reader also offers one-key reset to factory settings.
Weighing only 251.8 g (179×70×40.5 mm), this ATP swab machine is lightweight and portable. The built-in lithium battery supports extended use or simultaneous charging and operation. Automatic zero-calibration ensures accuracy every time.
The ATP testing meter features a straightforward operation interface and workflow with a low learning curve—no professional training required. Power on, swab the target surface, insert the swab, and get results in 10 seconds.
The ATP bioluminescence meter is compatible with major ATP fluorescence detectors on the market. The dedicated swabs feature a sealing protective plug to maintain liquid stability and reagent activity.
The ATP monitor comes with a durable aluminum alloy carrying case, making it convenient for outdoor testing and portability. The case protects the instrument during transport and storage.
Manufactured in accordance with JJF 1828-2020 "Calibration Specification for ATP Fluorescence Detectors," this ATP meter is quality assured. It comes with a 2-year warranty for worry-free use under normal operating conditions.
Your Need | Recommended Model |
|---|---|
Rapid hygiene monitoring in food processing | BATP-100 – 10-second test, 3-color alarm, portable. |
Pharmaceutical cleanroom environmental monitoring | BATP-100 – High sensitivity, data management, USB export. |
Water treatment facility screening | BATP-100 – Coliform detection, 2,000 record storage. |
Press and hold the power button for 2 seconds to turn on the instrument. It will automatically enter the 10-second zeroing calibration mode.
After the swab returns to room temperature, collect the sample from the target surface.
Insert the swab into the instrument, and the rapid test will be completed in 10 seconds with the reading displayed.
Clean the instrument with a soft, dry cloth.
Do not immerse in water.
Store in the carrying case when not in use.
Precautions:
Use dedicated swabs for standardized sampling.
Do not touch the swab tip before sampling.
Ensure the instrument is calibrated before use.
Store in a dry environment at room temperature.
Our ATP meter is widely used in:
Food Processing Lines: Rapid microbial contamination screening on surfaces and equipment.
Medical Equipment Surfaces: Hygiene monitoring in hospitals and clinics.
Pharmaceutical Cleanrooms: Environmental monitoring for sterility assurance.
Water Treatment Facilities: Bacterial screening in water systems.
Environmental Monitoring: General hygiene assessment in public facilities.
A: The ATP meter delivers results in just 10 seconds with a one-button start.
A: This ATP tester has a detection limit of ≤1.0 CFU/mL and accuracy up to 2×10⁻¹⁵ mol ATP.
A: Yes. The ATP detection device supports USB Type-C data transfer to PC in CSV format (Excel/WPS compatible).
A: The ATP luminometer features a built-in lithium battery that supports extended use or simultaneous charging and operation.
A: Yes. It is manufactured in accordance with JJF 1828-2020 "Calibration Specification for ATP Fluorescence Detectors."
Whether you are a food safety inspector, pharmaceutical QA specialist, or environmental monitor, BKMAMLAB ATP meters offer the perfect combination of speed, accuracy, and portability. Choose the BATP-100 model for reliable on-site hygiene monitoring.
Order your BKMAMLAB ATP meter today! Bulk inquiries and custom configurations are welcome – contact our team for assistance.