loading
| Availability: | |
|---|---|
| Quantity: | |
The BKMAMLAB laboratory shaker (also referred to as a lab shaker, orbital shaker, or rocking shaker) is a versatile instrument designed for efficient mixing, staining, and incubation in life science laboratories. It provides three independent motion modes: horizontal (orbital), rocking (see-saw), and 3D motion—making it ideal for electrophoresis gel staining and destaining, Western blot antibody incubation, cell culture, and membrane transfer.
Available in four series—TM, DS, SYC, and SYC Split—this digital orbital shaker covers load capacities from 2 kg to 8 kg and working plate sizes from 270×245 mm to 338×308 mm. Equipped with a stepper motor, intelligent PID speed regulation, automatic leveling, power-off memory, and stall protection, this benchtop shaker ensures precise, reliable, and safe operation for a wide range of laboratory applications.
Parameter | TM Series | DS Series | SYC Series | SYC Split Series |
|---|---|---|---|---|
Recommendation Reason | High load capacity | High cost-performance, large tray area, 3D motion | Large swing amplitude, strong mixing force | Split design, can be placed in refrigerator/incubator |
Load Capacity | 8 kg | 5 kg | 2 kg | 2 kg |
Working Plate Size | 270 × 245 mm | 338 × 308 mm | 317 × 245 mm | 317 × 245 mm |
Swing Amplitude | 9° | 10° | 20° | 20° |
Orbit Radius | 12 mm | 15 mm | 10 mm | 10 mm |
Motor Type | DC motor | Stepper motor | Stepper motor | Stepper motor |
Operating Mode | Orbital / Rocker | Orbital / Rocker / 3D | Orbital / Rocker | Orbital / Rocker |
Weight | 3.5 kg | 7.6 kg | 4.5 kg | 4.5 kg |
Parameter | TM-180Pro | TM-180 | TM-90C |
|---|---|---|---|
Motion Mode | Orbital (circular) | Orbital (circular) | Rocking (pendulum) |
Time Range | 1 min – 99 h 59 min | 1 min – 120 min | / |
Speed Range | 50–210 rpm | 50–210 rpm | / |
Swing Amplitude | / | / | 9° |
Orbit Radius | 12 mm | 12 mm | / |
Load Capacity | 8 kg | 8 kg | 7 kg |
Platform Size | 270 × 245 mm | 270 × 245 mm | 270 × 245 mm |
Display | LED | LED | / |
Weight | 3.5 kg | 3.5 kg | 4.2 kg |
Motor Type | DC gear motor | DC gear motor | DC gear motor |
Series | DS-2H200 | DS-2S100 | DS-3D100 |
|---|---|---|---|
Motion Mode | Orbital | Rocking | 3D |
Time Range | 0–999 h 59 min | 0–999 h 59 min | 0–999 h 59 min |
Speed Range | 0–200 rpm | 0–200 rpm | 0–200 rpm |
Swing Amplitude | / | 10° | 10° |
Orbit Radius | 15 mm | / | / |
Load Capacity | 5 kg | 5 kg | 5 kg |
Platform Size | 338 × 308 mm | 338 × 308 mm | 338 × 308 mm |
Display | LCD | LCD | LCD |
Weight | 7.6 kg | 7.6 kg | 7.6 kg |
Motor Type | Stepper motor | Stepper motor | Stepper motor |
Series | SYC-P200 | SYC-2T100 | SYC-FP200 | SYC-FZ100 |
|---|---|---|---|---|
Motion Mode | Orbital | Rocking | Orbital | Rocking |
Time Range | 0–999 h 59 min | 0–999 h 59 min | 0–999 h 59 min | 0–999 h 59 min |
Speed Range | 0–200 rpm | 0–200 rpm | 0–200 rpm | 0–200 rpm |
Swing Amplitude | / | 20° | / | 20° |
Orbit Radius | 10 mm | / | 10 mm | / |
Load Capacity | 2 kg | 2 kg | 2 kg | 2 kg |
Platform Size | 317 × 245 mm | 317 × 245 mm | 317 × 245 mm | 317 × 245 mm |
Display | LCD | LCD | LCD | LCD |
Weight | 4.5 kg | 4.5 kg | 4.5 kg | 4.5 kg |
Motor Type | Stepper motor | Stepper motor | Stepper motor | Stepper motor |
This laboratory shaker offers four operating modes: orbital, linear, rocking, and 3D motion. The 3D compound motion provides faster and more uniform mixing than conventional modes, delivering superior efficiency for gel staining, Western blot incubation, and cell culture. The 3D shaker capability makes it a versatile choice for diverse laboratory workflows.
Driven by a stepper motor with an intelligent PID system, this digital orbital shaker ensures precise speed regulation and smooth start/acceleration/deceleration. This prevents sudden movements that could tip containers, protecting both samples and operators. The stepper motor also offers low noise, long service life, and maintenance-free operation.
The lab shaker features automatic leveling upon stop—the tray automatically returns to the horizontal position after operation ends, preventing sample tipping. Additionally, it includes stall protection: when the load is unbalanced, the shaker automatically stops and alarms, then resumes operation after the load is balanced, preventing damage to experimental samples.
The power-off memory function retains operating parameters when power is interrupted, preventing loss of settings after power is restored. This laboratory shaker ensures that your experiment can continue seamlessly, saving time and reducing errors.
The TM series offers a maximum load capacity of 8 kg, making it ideal for high-load applications. The DS series features a large tray area and anti-rust treatment on the base plate, resisting chemical corrosion for enhanced durability. The SYC series provides large swing amplitude (20°) for strong mixing force.
The TM-90C model includes a built-in high-capacity battery, allowing it to be used without being plugged in. This offers greater flexibility in various application scenarios, especially where power outlets are limited.
The DS series features a large tray design that accommodates oversized containers with ease. The DS-3D100 model offers 3D compound motion, which is faster and more uniform than conventional modes, delivering superior mixing efficiency.
The SYC series includes automatic leveling upon stop and stall protection. The SYC-FP200 and SYC-FZ100 models feature a split design, allowing the main unit to be placed inside refrigerators or incubators and controlled externally.
Your Need | Recommended Series |
|---|---|
High load capacity (up to 8 kg) | TM Series – DC motor, orbital/rocker, ideal for decolorizing. |
High cost-performance, large tray, 3D motion | DS Series – Stepper motor, orbital/rocker/3D, 5 kg load. |
Large swing amplitude, strong mixing force | SYC Series – Stepper motor, orbital/rocker, 20° swing. |
Split design for refrigerator/incubator use | SYC Split Series – Main unit and control handle separated. |
Place the laboratory shaker on a flat, stable, and heat-resistant work surface.
Ensure the power supply matches the required voltage (100–240 V).
Load samples evenly on the working plate to avoid imbalance.
Use the control panel to set the desired mode (orbital, rocking, or 3D), speed, and time.
For TM series, use the knob or buttons; for DS/SYC series, use the digital display.
Press the start button. The shaker will begin with smooth acceleration.
Do not move the shaker during operation.
If the load becomes unbalanced, the stall protection will activate, stopping the shaker and sounding an alarm.
When the operation ends, the tray automatically returns to the horizontal position (for models with auto leveling).
Turn off the power and unplug the shaker.
Clean the tray and base with a mild detergent. Do not immerse in water.
Precautions:
Always place the shaker on a flat, stable, and heat-resistant work surface.
Do not use the shaker if the power cord or plug is damaged.
Do not move the shaker during operation.
If the shaker does not operate properly, unplug the power cord and contact your supplier.
If residual liquid is present in the tray, clean it promptly.
If not used for an extended period, remove all items from the shaker.
Store the shaker in a dry, frost-free environment.
Our laboratory shaker is widely used in:
Gel Staining and Destaining: Electrophoresis gel processing.
Western Blot: Antibody incubation to reduce antibody consumption.
Cell Culture: Gentle mixing and washing of cell cultures.
Sample Mixing: Homogenization of chemical and biological samples.
Microbiological and Immunological Hybridization: Plate and tube mixing.
A: TM series offers high load capacity (up to 8 kg) with DC motor. DS series offers high cost-performance with large tray and 3D motion, stepper motor. SYC series offers large swing amplitude (20°) and split design options.
A: Yes. The SYC Split series features a split design where the main unit can be placed inside a refrigerator or incubator, while the control handle remains outside.
A: The TM series supports up to 8 kg, the DS series up to 5 kg, and the SYC series up to 2 kg.
A: Yes. All models feature power-off memory, which retains operating parameters when power is interrupted.
A: The shaker includes automatic leveling upon stop, stall protection (auto stop and alarm upon unbalanced load), and power-off memory. Some models also have anti-rust treatment on the base plate.
Whether you are a molecular biologist, biochemist, or laboratory technician, BKMAMLAB laboratory shakers offer the perfect combination of multi-mode motion, precise control, and safety features. Choose from TM, DS, SYC, or SYC Split series to match your specific application needs.
Order your BKMAMLAB laboratory shaker today! Bulk inquiries and custom configurations are welcome – contact our team for assistance.