loading
The Labshark plastic vacuum desiccator (also referred to as a lab vacuum desiccator, laboratory desiccator, or vacuum desiccator chamber) is a high-performance instrument designed for vacuum drying preservation of biochemical reagents, pharmaceuticals, and sensitive materials. Made of imported polycarbonate by injection molding, this desiccant chamber features a 4mm wall thickness (15% increase) with rib reinforcement design for enhanced pressure resistance.
With a vacuum stability of less than 6% change over 31 days, this vacuum desiccator ensures long maintenance time and reliable performance. The grease-free sealing system uses silicone rubber O-rings, while the dedicated metal needle valve and quick-connect fitting support dual-valve installation for vacuum evacuation and inert gas introduction. Available in 150mm, 250mm, 300mm, and 400mm sizes, this desiccator jar is the ideal vacuum desiccator for laboratory applications.
Model | 150mm | 250mm | 300mm | 400mm |
|---|---|---|---|---|
Max. Outer Diameter | 187 mm | 282 mm | 343 mm | 452 mm |
Inner Diameter | 159 mm | 251 mm | 306 mm | 408 mm |
Container Area Height | 151 mm | 192 mm | 245 mm | 328 mm |
Base Outer Diameter | 143 mm | 206 mm | 179 mm | 239 mm |
Total Height | 270 mm | 364 mm | 388 mm | 484 mm |
Related Products: Hose, glass vacuum desiccator, vacuum pump.
The vacuum desiccator maintains a vacuum level change of less than 6% within 31 days after evacuation, ensuring long maintenance time and reliable sample protection. This vacuum desiccator chamber is ideal for long-term storage of sensitive materials.
Made of imported polycarbonate by injection molding, this plastic vacuum desiccator features a 15% increased wall thickness of 4mm and a rib reinforcement design for enhanced pressure resistance. The durable construction ensures long service life.
The laboratory desiccator features a grease-free sealing system with silicone rubber O-rings. Sealed pipe threads combined with sealing rings and gaskets prevent air leakage and stress cracks, ensuring a reliable vacuum seal.
This vacuum desiccator is equipped with a dedicated metal needle valve and a quick-connect fitting for soft nylon tubing. It supports dual-valve installation for both vacuum evacuation and inert gas introduction, making it a versatile desiccator jar for various applications.
Available in four sizes (150mm, 250mm, 300mm, 400mm), this lab vacuum desiccator accommodates different sample volumes and laboratory space requirements. The vacuum desiccator for laboratory series provides flexible options for every need.
The desiccator is suitable for vacuum drying preservation of biochemical reagents, pharmaceuticals, and other sensitive materials. It also supports oxidation prevention using inert gas, making it an essential tool for laboratory desiccators in research and quality control.
Your Need | Recommended Model |
|---|---|
Small sample storage | 150mm – Max outer diameter 187mm, total height 270mm. |
Standard laboratory use | 250mm – Max outer diameter 282mm, total height 364mm. |
Medium capacity | 300mm – Max outer diameter 343mm, total height 388mm. |
Large capacity | 400mm – Max outer diameter 452mm, total height 484mm. |
All models feature the same vacuum stability, polycarbonate construction, and dual-valve compatibility.
Place the vacuum desiccator on a stable, flat surface.
Check that the silicone O-ring and sealing gaskets are properly seated.
Connect the vacuum pump to the needle valve using the quick-connect fitting and nylon tubing.
Place your samples inside the desiccator chamber.
Ensure the samples are properly contained to prevent spillage.
Position the lid carefully onto the base.
Close the needle valve.
Turn on the vacuum pump and evacuate the chamber to the desired vacuum level.
Monitor the vacuum gauge (if equipped) to confirm the vacuum level.
For oxidation prevention, connect an inert gas source to the second valve (if installed).
Slowly introduce inert gas into the chamber, then close the valve.
After use, release the vacuum slowly before opening the lid.
Clean the desiccator with a mild detergent and soft cloth.
Do not use abrasive cleaners or solvents that may damage the polycarbonate.
Precautions:
Do not exceed the maximum vacuum level recommended for the desiccator.
Always release vacuum slowly to prevent sample disturbance.
Do not use the desiccator with corrosive chemicals that may attack polycarbonate.
Inspect the O-rings regularly and replace if worn or damaged.
Our vacuum desiccator is widely used in:
Biochemical Reagent Storage: Vacuum drying preservation of enzymes, antibodies, and other reagents.
Pharmaceuticals: Storage of moisture-sensitive drugs and intermediates.
Material Science: Protection of sensitive materials from oxidation and moisture.
Electronics: Storage of electronic components in a dry, vacuum environment.
Research Laboratories: General vacuum drying and inert gas protection.
Whether you need a vacuum desiccator with pump for complete setup, a desiccator accessories kit, or a standalone desiccator jar, Labshark provides reliable and durable solutions.
A: The vacuum desiccator maintains a vacuum level change of less than 6% within 31 days after evacuation.
A: It is made of imported polycarbonate by injection molding with a 4mm wall thickness and rib reinforcement design.
A: Yes. The vacuum desiccator supports dual-valve installation for both vacuum evacuation and inert gas introduction.
A: This lab vacuum desiccator is available in 150mm, 250mm, 300mm, and 400mm sizes.
A: Yes. The vacuum desiccator is compatible with standard vacuum pumps and includes a quick-connect fitting for soft nylon tubing.
Whether you are a researcher, quality control specialist, or laboratory manager, Labshark plastic vacuum desiccators offer the perfect combination of vacuum stability, durable construction, and versatile valve configuration. Choose from 150mm to 400mm models to match your specific storage needs.
Order your Labshark vacuum desiccator today! Bulk inquiries and custom configurations are welcome – contact our team for assistance.