loading
| Availability: | |
|---|---|
| Quantity: | |
BKM presents its premium infrared sterilizer (bacti-cinerator), a safe, open-flame-free alcohol lamp alternative designed for rapid and efficient sterilization. Unlike traditional lab burners that produce open flames and noxious fumes, this flame-free loop sterilizer ensures maximum safety for your biosafety cabinet and clean bench operations.
Available in three models—BIS-14, BIS-35, and TS950S—this microbiology loop sterilizer utilizes a high-performance ceramic core to reach sterilization temperatures within just 3-5 seconds (or 1 second for the TS950S). It is the perfect lab burner substitute for modern research and clinical labs, offering convenience without compromising on safety.
Parameter | BIS-14 | BIS-35 | TS950S |
|---|---|---|---|
Input Voltage | AC 220V, 50Hz | AC 220V, 50Hz | 220–240V, 50/60Hz |
Operating Power | 150W | 300W | 600W |
Max Center Temperature | 825°C ± 50°C | High Temperature | 900 – 1300°C |
Max Item Outer Diameter | 14 mm | 35 mm | 15 mm |
Total Heating Zone Length | 150 mm | 100 mm | 100 mm |
Heating Time to Max Temp | 20 min | 1 s | 1 s |
Fuse | 250V, 3A, 5×20mm | 250V, 3A, 5×20mm | 110V, 6.3A / 220V, 3.15A |
Operating Ambient Temp | 5°C – 40°C | 5°C – 40°C | 5°C – 40°C |
Package Dimensions | 340×280×190 mm | 150×210×200 mm | 150×210×200 mm |
Power Cord Length | 1 m | 1 m | 1.5 m |
Package Weight | 1.8 kg | 2.5 kg | 2.5 kg |
Unlike traditional alcohol lamps, this flame-free sterilizer uses a high-temperature ceramic core to generate infrared heat, eliminating open flames and fire hazards. The BIS series features an automatic power-off function upon tipping, ensuring operator safety even in crowded or mobile lab environments. This makes it the ultimate biosafety cabinet loop sterilizer for microbiology work.
With a sterilization time of 3-5 seconds (just 1 second for TS950S), this high temperature loop sterilizer allows you to sterilize inoculation loops and needles efficiently between experiments. The TS950S reaches a maximum temperature of 900–1300°C, ensuring complete incineration of microbial contaminants at the core level.
This needle sterilizer for lab is primarily used in biosafety cabinets, clean benches, and mobile carts. It safely replaces alcohol lamps, providing a convenient, maintenance-friendly solution for sterilizing inoculation loops, needles, and other small metal laboratory instruments.
The body is constructed from high-temperature-resistant, flame-retardant materials for long-term durability. Weighing as little as 1.8 kg, its compact footprint makes it easy to move and install in various lab spaces.
Your Need | Recommended Model |
|---|---|
Standard sterilization of inoculation loops (≤14mm) | BIS-14 – 150W, 825°C, 1.8kg lightweight. |
Sterilization of larger instruments (≤35mm) | BIS-35 – 300W, larger diameter, faster heat-up (1s). |
Ultra-rapid sterilization, higher temperature (≤15mm) | TS950S – 600W, 900–1300°C, 1s heat-up, 2.5kg. |
Whether you need a 14mm loop sterilizer for routine lab tasks, a 35mm sterilizer for larger tools, or the high-speed TS950S, BKM provides the exact solution for your workflow.
Place the sterilizer on a stable, flat, and vibration-free work surface. Do not install on uneven or shaky surfaces.
Connect the power cord. Ensure your hands are dry before plugging in or switching the power on.
Wait for the unit to reach operating temperature. Insert the inoculation loop or needle into the heating chamber for 3-5 seconds (or 1 second for TS950S) to achieve efficient sterilization.
Turn off the power after use. Never perform maintenance or wipe the instrument while it is powered on. Avoid scratching or bumping the heating chamber wall.
Precautions:
Do not plug/unplug with wet hands.
Continuous operation should not exceed 6 hours.
The instrument angle is not adjustable – do not attempt to modify it.
For BIS series, if the unit tips over, it will automatically cut off power for safety.
Our microbiology loop sterilizer is widely used in:
Microbiology Research: Sterilizing inoculation loops, spreaders, and forceps.
Clinical Labs: Disinfecting needles and small surgical instruments.
Pharmaceutical Quality Control: Maintaining sterility during sample handling.
Environmental Monitoring: Field testing stations and mobile carts.
Educational Institutions: Teaching labs requiring safe, flame-free sterilization.
A: Our flame-free sterilizer offers the perfect lab burner substitute. It eliminates open flames, reduces fire hazards, and avoids the noxious fumes produced by alcohol. With rapid heating (1-5 seconds), it allows safe operation inside biosafety cabinets without the risk of accidental fires.
A: The BIS series reaches sterilization temperature within 3-5 seconds. The TS950S heats up in just 1 second, making it the fastest option.
A: For the BIS-14 and BIS-35 models, the device features an automatic power-off function upon tipping, instantly cutting off power to prevent accidents.
A: Continuous operation is recommended for no more than 6 hours to prevent overheating and extend product lifespan.
Whether you are a microbiologist, lab technician, or researcher, BKM infrared sterilizers offer the perfect combination of safety, speed, and reliability. Choose from BIS-14, BIS-35, or TS950S to match your sterilization needs.
Order your BKM infrared sterilizer today! Bulk inquiries and custom configurations are welcome – contact our team for assistance.